Language
Reactor
We offer a family of reactors that enhance productivity by reducing nuisance tripping, lowering harmonic distortion and minimizing long lead effects.
RZ
Line Side & Load Side Reactors
Home » Products » Reactors » RL Line and Load Reactors
RL Line and Load Reactors
Peace of mind included.
Our RL Line/Load Reactors are best-in class power quality units with a long history of proven performance for lowering harmonics caused by variable frequency drives (VFDs). Rugged and robust, they are unequalled in absorbing power line disturbances that can damage or shut down variable frequency drives (VFDs) and other sensitive equipment. They work on both the line (input) side and load (output) side to give you an easy solution that reduces nuisance tripping, reduces harmonic distortion and minimizes long lead effects.
Related Links:
Should I use an RL or an RLW Reactor?
Product Brochure
Solutions Catalog
Detailed Product Data
Application Notes
Technical Manual
RL Reactor Specification Table
RL Reactor Specs
Improved power quality, enhanced productivity and complete peace of mind are easy with RL Line/Load Reactors.
Best-in-class line/load reactors
Most robust, highest continuous service factor
Low watts loss
Performance and durability that is unmatched by the competition
3-Phase Reactors: Line/Load Selection Table 15/11-100/75 HP/kw
3-Phase Reactors: Line/Load Selection Table 125/93 750/550 HP/kw
A CAD drawing in web image format is available by clicking on the part number.
Line/Load Selection Table – 1/.75-10/7.5 HP/kw
208-690 Volts, 50/60 hz (Open Type)
Ratings HP/kw 1/.75 1.5/1.1 2/1.5 3/2.2 5/3.7 7.5/5.5 10/7.5
208 Volts
50/60 HZ 3% Impedance RL-00801 RL-00801 RL-00801 RL-01801 RL-02501 RL-03501 RL-05501
208 Volts
50/60 HZ 5% Impedance RL-00802 RL-00802 RL-01202 RL-01802 RL-02502 RL-03502 RL-05502
240 Volts
50/60 HZ 3% Impedance RL-00802 RL-00801 RL-00801 RL-01201 RL-01801 RL-02501 RL-03501
240 Volts
50/60 HZ 5% Impedance RL-00803 RL-00802 RL-00802 RL-01202 RL-02502 RL-03502 RL-03502
400 Volts
50/60 HZ 3% Impedance RL-00403 RL-00402 RL-00402 RL-00803 RL-00802 RL-01202 RL-01802
400 Volts
50/60 HZ 5% Impedance RL-00202 RL-00404 RL-00403 RL-00804 RL-00803 RL-01203 RL-01803
480 Volts
50/60 HZ 3% Impedance RL-00201 RL-00402 RL-00402 RL-00803 RL-00802 RL-01202 RL-01802
480 Volts
50/60 HZ 5% Impedance RL-00202 RL-00404 RL-00403 RL-00804 RL-00803 RL-01203 RL-01803
600 Volts
50/60 HZ 3% Impedance RL-00202 RL-00202 RL-00403 RL-00402 RL-00803 RL-01202 RL-01202
600 Volts
50/60 HZ 5% Impedance RL-00203 RL-00202 RL-00404 RL-00404 RL-00804 RL-01203 RL-01203
690 Volts
50/60 HZ 2% Impedance Consult
Factory Consult
Factory Consult
Factory RL-00403 RL-00402 RL-00801 RL-01202
690 Volts
50/60 HZ 3% Impedance Consult
Factory Consult
Factory Consult
Factory RL-00402 RL-00404 RL-00804 RL-01203
CAD file icon A CAD drawing in web image format is available by clicking on the part number.
Line/Load Selection Table – 15/11-100/75 HP/kw
208-690 Volts, 50/60 hz (Open Type)
Ratings HP/kw 15/11 20/15 25/18.5 30/22 40/30 50/37.5 60/45 75/55 100/75
208 Volts
50/60 HZ 3%
Impedance RL-
05501 RL-
08001 RL-
10001 RL-
10001 RL-
13001 RL-
16001 RL-
20001B14 RL-
25001B14 RL-
32001B14
208 Volts
50/60 HZ 5%
Impedance RL-
04501 RL-
05501 RL-
08001 RL-
13002 RL-
16002 RL-
20002B14 RL-
20002B14 RL-
25002B14 RL-
32002B14
240 Volts
50/60 HZ 3%
Impedance RL-
04501 RL-
05501 RL-
08001 RL-
10001 RL-
13001 RL-
13001 RL-
16001 RL-
20001B14 RL-
25001B14
240 Volts
50/60 HZ 5%
Impedance RL-
05502 RL-
08002 RL-
10001 RL-
08001 RL-
13002 RL-
16002 RL-
16002 RL-
20002B14 RL-
25002B14
400 Volts
50/60 HZ 3%
Impedance RL-
02502 RL-
03502 RL-
04502 RL-
04502 RL-
08002 RL-
08002 RL-
10002 RL-
13002 RL-
16002
400 Volts
50/60 HZ 5%
Impedance RL-
02503 RL-
03503 RL-
04503 RL-
05503 RL-
08003 RL-
10003 RL-
10003 RL-
13003 RL-
16003
480 Volts
50/60 HZ 3%
Impedance RL-
02502 RL-
03502 RL-
03502 RL-
04502 RL-
05502 RL-
08002 RL-
10002 RL-
10002 RL-
13002
480 Volts
50/60 HZ 5%
Impedance RL-
02503 RL-
03503 RL-
03503 RL-
05503 RL-
05503 RL-
08003 RL-
10003 RL-
10003 RL-
13003
600 Volts
50/60 HZ 3%
Impedance RL-
01802 RL-
02502 RL-
02502 RL-
03502 RL-
04502 RL-
05502 RL-
08002 RL-
08002 RL-
10002
600 Volts
50/60 HZ 5%
Impedance RL-
01803 RL-
02503 RL-
02503 RL-
03503 RL-
04503 RL-
05503 RL-
08003 RL-
08003 RL-
10003
690 Volts
50/60 HZ 2%
Impedance RL-
01202 RL-
01802 RL-
02502 RL-
02502 RL-
03502 RL-
04502 RL-
05502 RL-
05502 RL-
08002
690 Volts
50/60 HZ 3%
Impedance RL-
01203 RL-
01803 RL-
02503 RL-
02503 RL-
03503 RL-
04503 RL-
04502 RL-
05503 RL-
08003
CAD file icon A CAD drawing in web image format is available by clicking on the part number.
Line/Load Selection Table – 125/93 750/550 HP/kw
208-690 Volts, 50/60 hz (Open Type)
Ratings HP/kw 125/93 150/112 200/150 250/187 300/225 350/262 400/300 500/375 600/450 700/550
208 Volts
50/60 HZ 3%
Impedance RL-
40001B14 RL-
50001B14 RL-
60001 RL-
75001 RL-
85001B14 RL-
100001B14 RL-
120001B14 RL-
140001 Consult
Factory Consult
Factory
208 Volts
50/60 HZ 5%
Impedance RL-
40002B14 RL-
50002 RL-
75002 RL-
75002 RL-
90002B14 RL-
100002B14 RL-
120002B14 RL-
150002 Consult
Factory Consult
Factory
240 Volts
50/60 HZ 3%
Impedance RL-
32001B14 RL-
40001B14 RL-
50001B14 RL-
60001 RL-
75001 RL-
85001B14 RL-
100001B14 RL-
120001B14 Consult
Factory Consult
Factory
240 Volts
50/60 HZ 5%
Impedance RL-
40002B14 RL-
40002B14 RL-
60002 RL-
75002 RL-
75002 RL-
85002B14 RL-
100002B14 RL-
140002 Consult
Factory Consult
Factory
400 Volts
50/60 HZ 3%
Impedance RL-
20002B14 RL-
20002B14 RL-
32002B14 RL-
40002B14 RL-
40002B14 RL-
50002 RL-
60002 RL-
75002 RL-
85002B14 RL-
90002B14
400 Volts
50/60 HZ 5%
Impedance RL-
20003B14 RL-
20003B14 RL-
32003B14 RL-
40003B14 RL-
40003B14 RL-
50003 RL-
60003 RL-
75003 RL-
85003B14 RL-
90003B14
480 Volts
50/60 HZ 3%
Impedance RL-
16002 RL-
20002B14 RL-
25002B14 RL-
32002B14 RL-
40002B14 RL-
50002 RL-
50002 RL-
60002 RL-
75002 RL-
85002B14
480 Volts
50/60 HZ 5%
Impedance RL-
16003 RL-
20003B14 RL-
25003B14 RL-
32003B14 RL-
40003B14 RL-
50003 RL-
50003 RL-
60003 RL-
75003 RL-
85003B14
600 Volts
50/60 HZ 3%
Impedance RL-
13002 RL-
16002 RL-
20002B14 RL-
25002B14 RL-
32002B14 RL-
32002B14 RL-
40002B14 RL-
50002 RL-
60002 RL-
75002
600 Volts
50/60 HZ 5%
Impedance RL-
13003 RL-
16003 RL-
20003B14 RL-
25003B14 RL-
32003B14 RL-
32003B14 RL-
40003B14 RL-
50003 RL-
60003 RL-
75003
690 Volts
50/60 HZ 2%
Impedance RL-
10002 RL-
13002 RL-
16002 RL-
20002B14 RL-
25002B14 RL-
25002B14 RL-
32002B14 RL-
40002B14 RL-
40002B14 RL-
50002
690 Volts
50/60 HZ 3%
Impedance RL-
10003 RL-
13003 RL-
16003 RL-
20003B14 RL-
25003B14 RL-
25003B14 RL-
32003B14 RL-
40003B14 RL-
50003 RL-
50003