Email: tap.part@engineer.com
Manostar gauge
WO81
High-precision differential pressure gauge
Abundant lineup
3 types of outer shape, 3 types of needle placement, 24 types of pressure range from 50Pa to 100kPa, ± 50Pa to ± 3kPa
Easy-to-read wide-angle scale
Since the polarity of the base can be changed, piping is possible without crossing the tubes.
Also supports air volume and speed scales
Also for monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Click here to download various catalogs / instruction manuals, etc.
WO71
Flat type micro differential pressure gauge N type, R type
Thin design, smart piping with rotary base as standard equipment
Achieves the thinnest thickness of 29.2 mm as a manostar gauge
Small differential pressure gauge FS type, PS type
Equipped as standard with a needle that is convenient for setting indicators for planned differential pressure and limit value
Various piping connections are possible
Polarity can be changed by simply exchanging the high-pressure side and low-pressure side caps * Side piping only
Also for monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Click here to download various catalogs / instruction manuals, etc.
FR51A
Edgewise micro differential pressure gauge
It has excellent instruction linearity, hysteresis, and reproducibility, and can measure the minute differential pressure region with high accuracy.
There are three types of scales: horizontal scale type, vertical scale type, and horizontal scale type for each color.
11 types of pressure range from 50Pa to 5kPa, ± 50Pa, ± 100Pa
The pipe base is a vinyl pipe or a rubber pipe (inner diameter 4)
Also for monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Click here to download various catalogs / instruction manuals, etc.
Manostar switch
MS99
Slight differential pressure switch
UL standard compliant product
Wide setting range by adopting multi-thread screw
Common general load and minute load
Easy to change the wiring direction
Operating pressure setting is as easy as adjusting the dial with scale.
Various piping connections are possible by exchanging the base (only the base exchange type)
Lineup of EC directive (CE marking) compliant products (rated voltage 30VDC or less)
For detecting clogging of air conditioning filters, monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Click here to download various catalogs / instruction manuals, etc.
MS99S
Intrinsically safe explosion-proof micro differential pressure switch
Explosion-proof performance Ex ia ⅡC T6 Ga
For detecting clogging of air conditioning filters, monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Click here to download various catalogs / instruction manuals, etc.
MS61A-RA
Small differential pressure switch
Single pole normally open sealed type
Compact and lightweight type that can be installed in any space
6 types of pressure range from 120Pa to 6kPa
Easy operation to set the operating pressure just by adjusting the scale knob
The pipe base is a vinyl pipe or a rubber pipe (inner diameter 4)
For detecting clogging of air conditioning filters, monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
The "MS61A-RA type", which was reopened in September 2019, is a non-UL standard compliant product.
Click here to download various catalogs / instruction manuals, etc.
Manostar Digital Sensor
QDP33
30 x 30 type digital micro differential pressure sensor
Connector connection type
UL standard, EC directive (CE marking) compliant product
16 types of pressure range, 10Pa to 2kPa, ± 10Pa to ± 2kPa
Equipped with an in-house developed capacitive sensor
Industry's smallest class
Baptized design and visibility
Also for monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Ultra-ultra-low pressure range 10Pa is ideal for measuring room pressure in clean rooms and negative pressure rooms that comply with CDC guidelines.
Click here to download various catalogs / instruction manuals, etc.
EMD8A
24 x 48 type digital micro differential pressure sensor
Connector connection type
UL standard, EC directive (CE marking) compliant product
14 types of pressure range, 50Pa to 5kPa, ± 50Pa to ± 500Pa
Designed for ease of incorporation into equipment
Equipped with various functions such as display, comparison output, and analog output
12mm high red LED display with excellent visibility
Also for monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Click here to download various catalogs / instruction manuals, etc.
EMD7
48 x 48 type digital micro differential pressure sensor
Terminal connection type
UL standard, EC directive (CE marking) compliant product
Eight types of pressure range from 100Pa to 5kPa
Alarm function mode can be set according to the application
Also for monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Click here to download various catalogs / instruction manuals, etc.
Manostar transmitter
EMT1
High-precision differential pressure transmitter
Wide range variation 33 types from 10Pa to 100kPa, ± 10Pa to ± 5kPa
Achievements in the advanced differential pressure management field
Piping connection port can be selected from vinyl pipe and metal pipe
For detecting clogging of air conditioning filters, monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Click here to download various catalogs / instruction manuals, etc.
EMTGP1
Corrosion-resistant micro differential pressure transmitter <for negative pressure measurement only>
Ideal for static pressure monitoring of exhaust ducts containing corrosive gas
For negative pressure measurement only
Five types of pressure range from -200Pa to -2kPa
For detecting clogging of air conditioning filters, monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Cannot be used to measure flammable gas
Click here to download various catalogs / instruction manuals, etc.
EMT1H (ia)
Intrinsically safe explosion-proof micro differential pressure transmitter
Explosion-proof performance Ex ia ⅡC T4 Ga
Manostar transmitter and safety barrier set
There are 27 types of pressure range, 10Pa to 100kPa and ± 10Pa to ± 100Pa.
Piping connection port can be selected from vinyl pipe and metal pipe
For detecting clogging of air conditioning filters, monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Click here to download various catalogs / instruction manuals, etc.
EMT1H (ic) End of production in 2019
Intrinsically safe explosion-proof micro differential pressure transmitter
Explosion-proof performance Ex ic ⅡC T4 Gc
Manostar transmitter and safety barrier set
There are 27 types of pressure range, 10Pa to 100kPa and ± 10Pa to ± 100Pa.
Piping connection port can be selected from vinyl pipe and metal pipe
For detecting clogging of air conditioning filters, monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Click here to download various catalogs / instruction manuals, etc.
EMT6
Small differential pressure transmitter
Zero adjustment is possible after installation with the zero adjustment trimmer
9 types of pressure range from 50Pa to 5kPa
Analog output: 4-20mA
For detecting clogging of air conditioning filters, monitoring negative pressure and negative pressure in clean rooms and isolation rooms!
Click here to download various catalogs / instruction manuals, etc.
Receiver
EMP5A
Display pressure, air volume, and wind speed in combination with Manostar transmitter
Built-in DC power supply for 2-wire micro differential pressure transmitter
Built-in square root extraction function
Equipped with 2 alarm outputs. Operation can be selected according to the application.
Front panel IP66 structure
Click here to download various catalogs / instruction manuals, etc.
Square root extraction unit
EMRT1
For measuring air volume and speed
The electric signal is square rooted and output as a current signal proportional to the air volume.
Air volume can be controlled by combining with Manostar transmitter
Click here to download various catalogs / instruction manuals, etc.
DC power supply
HWS15A
Can supply up to 15 24V DC power supplies
Can be used as a drive power supply for a 2-wire micro differential pressure transmitter 4 to 20 mA