Inductive positioning system
PMI80-F90-IE8-V15
< Analog output 4 mA ... 20 mA
< Adjustable switch points
< Measuring range 0 ... 80 mm
Dimensions
Button
LED Power
63
102
83
M5 (2x)
23 22
LED
S2 S1
S1 S2
41
M12 x 1
20 mA 4 mA
Technical Data
General specifications
Switching element function Analog current output with PNP binary NO
Object distance 0.5 ... 3 mm , recommended: 2 mm
Measurement range 0 ... 80 mm
Linearity range 1 ... 79 mm
Nominal ratings
Operating voltage UB 18 ... 30 V DC
Reverse polarity protection reverse polarity protected
Linearity error within measuring range: ± 0.8 mm
within linearity range: ± 0.4 mm
Repeat accuracy R ± 0.1 mm
Resolution 125 μm
Temperature drift ± 0.5 mm (-25 °C ... 70 °C)
No-load supply current I0 ≤ 40 mA
Operating voltage indicator LED green
1
Release date: 2020-03-23 Date of issue: 2020-10-16 Filename: 191137_eng.pdf
Pepperl+Fuchs Group Germany: +49 621 776 1111
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
Technical Data
Functional safety related parameters
MTTFd 300 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Switching output
Output type 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected
Operating current IL ≤ 100 mA
Switching window ± 1 mm
Switching hysteresis 0.4 mm
Voltage drop ≤ 3 V
Short-circuit protection pulsing
Analog output
Output type 1 current output: 4 ... 20 mA
Load resistor ≤ 400 Ω
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
IEC 60947-5-2:2007
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type 5-pin, M12 x 1 connector
Degree of protection IP67
Material
Housing ABS
Target mild steel, e. g. 1.0037, SR235JR (formerly St37-2)
Connection
+ UB
- UB
1
5
2
4
3
I
Q S1
Q S2
4-20 mA
IE8
Connection Assignment
1
3
4
5
2
Inductive positioning system PMI80-F90-IE8-V15
Release date: 2020-03-23 Date of issue: 2020-10-16 Filename: 191137_eng.pdf
2 Pepperl+Fuchs Group Germany: +49 621 776 1111
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
1 BN
2 WH
3 BU
4 BK
5 GY
Wire colors in accordance with EN 60947-5-2
(brown)
(white)
(blue)
(black)
(gray)
4
8
18
dimensions for the target object:
Linearity range
Measuring range
10 V/20 mA
0 V/4 mA
Accessories
BT-F90-W Damping element for sensors of type F90, F112, and F166; side hole
MH-F90 Mounting bracket for mounting of F90 sensors
V15-G-2M-PVC Female cordset, M12, 5-pin, PVC cable
V15-W-2M-PVC Female cordset, M12, 5-pin, PVC cable
Inductive positioning system PMI80-F90-IE8-V15
Release date: 2020-03-23 Date of issue: 2020-10-16 Filename: 191137_eng.pdf
3 Pepperl+Fuchs Group Germany: +49 621 776 1111
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
Release date: 2020-03-23 Date of issue: 2020-10-16 Filename: 191137_eng.pdf
PMI80-F90-IE8-V15
Pepperl+Fuchs Group Germany: +49 621 776 1111 4
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
Inductive positioning system
Operating instructions
• Safety information
• Sensor versions
The F90 linear position measurement system is available in 2 versions.
In the PMI...-F90-IU-V1 version, the position measuring system transmits current and voltage signals proportional to the
position of the damping element at the outputs.
The PMI...-F90-IE8-V15 version offers a current signal as well as the option of teaching in two switching points directly at the
sensor independently of one another at the press of a button, which is then indicated on two switching outputs. Two additional
LEDs indicate the output states of the two switching outputs.
Version PMI…-F90-IU-V1
Output signals: 4 mA ... 20 mA and 0 V ... 10 V
Version PMI…-F90-IE8-V15
Output signals: 4 mA ... 20 mA and 2 programmable switching amplifiers
• Programming the PMI…-F90-IE8-V15
The rear of the PMI...-F90-IE8-V15 sensor has two small, slightly recessed push buttons for programming the switching points.
The buttons are marked "teach in" and S1 for switching point S1 and S2 for switching point S2.
To teach in a switching point, proceed as follows:
- The position detection damping element must be placed at the relevant position, i.e. the switching point that you wish to
teach in.
- Press the corresponding push button for at least two seconds.
The associated switching state LED starts flashing to indicate that the sensor is now in “teach mode”.
- Press the button again to confirm the relevant switching point.
The switching state LED then lights up constantly as long as the damping element is not moved.
The switching point is now taught in and the associated switching point changes to an active state within an actuator
adjustment range of ± 1 mm around the taught switching point.
• Damping element
The linear position measurement system is adapted perfectly to the geometry of the damping
elements offered in our product range.
• Installation and operation
Instructions on installation
- Flush installation is possible
- to extend the measuring range, units from the -F90 linear position measurement system can be
connected in series (both behind and adjacent to one another) without a minimum distance.
- The minimum distance between the measuring field (framed area on the sensor front) and
mounting base or mounting elements on the damping element must be 3 mm.
• Operating information
The specified measurement accuracy is achieved with an actuator distance of 1 to 3 mm.
If the damping element leaves the measuring area (illustration below):
- the last valid value is retained at the voltage output (PMI…-F90-IU-V1 only) until the damping element enters the valid area
again.
- the last valid value is retained for 0.5 seconds at the current output (all types). The output then switches to a fault current of
3.6 mA until the damping element enters the valid area again.
Operation
This product may not be used in applications where personal
safety depends on the function of the device.
This product is not a safety component as described in EU
Machinery Directive.
Only the current output or the voltage output may be used. The
unused output must remain load free.
If the switching point is not confirmed within 80 seconds, the sensor
exits “teach mode” and continues operation with the previous values.
When using other damping elements,
always make sure that the active surface
of the damping element has a width of
exactly 8 mm and covers the entire width
of the sensor.
Warning
Note
Note
≥ 4
8
≥ 18
Note
3
Screw
3
Release date: 2020-03-23 Date of issue: 2020-10-16 Filename: 191137_eng.pdf
PMI80-F90-IE8-V15
Pepperl+Fuchs Group Germany: +49 621 776 1111 5
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
Inductive positioning system
- the switching amplifiers set to basic state after 0.5 seconds ("normally open").
• Defining the measuring range / measured position
The measured position of the damping element (actuator) is based on half of the width (center of the actuator). The measuring
range starts and finishes when half the width of the actuator covers the measurement field marked on the sensor when the
actuator makes a longitudinal movement (see left illustration above).
• Accessories
Straight cable:V1-G-2M-PVC (4-wire)
V15-G-2M-PVC (5-wire)
Angled cable:V1-W-2M-PVC (4-wire)
V15-W-2M-PVC (5-wire)
Damping elements Mounting bracket
BT-F90-W MH-F90
start of measuring range measured position end of measuring range
labeled measuring area
motion direction of actuator
width w of actuator
w/2
actuator