ต้องการสอบถามราคา รายละเอียดสินค้า กรุณาแจ้งยี่ห้อ รุ่น จำนวน เข้ามาที่
Mobile: 091-484-4332
21
Ed. 1/2016 www.elettrotec.com
Pagina 1 di 2
Sheet 1 of 2
30x30
C
37
D
B A
Pressacavo PG9
Cable clamp
T V
30x30
C
37
D
B A
Pressacavo PG9
Cable clamp
T V
30x30
G 1/4
37
D
12
A
CH 17
T V
Tensione massima 250 Vca
Tensione di lavoro 220 Vca
Intensità di corrente 3A (resistivi), 2A (induttivi)
Contatti elettrici SPDT
PMC N° cicli max a membrana 100/1’
PPC/PPCF N° cicli max a pistone 60/1’
Protezione IP 65 - DIN 40050
Connettore PG09 - DIN 43650
Corpo Alluminio anodizzato
Materiale fl angia di fi ssaggio Acciaio AVP
Maximum voltage 250 Vac
Working voltage 220 Vac
Current 3A (resistive), 2A (inductive)
C/O contact SPDT
PMC Max cycle rate - diaphragm type 100/min.
PPC/PPCF Max cycle rate - piston type 60/min.
Protection IP 65 - DIN 40050 see page 2
PG09 connector DIN 43650
Body Anodized aluminium
Mounting fl ange material Zinc plated steel
PMC/PPC/PPCF PRESSOSTATI REGOLABILI CON CONTATTI IN SCAMBIO
Adjustable pressure switches with SPDT contacts
CONNESSIONI ELETTRICHE DISPONIBILI / AVAILABLE ELECTRICAL CONNECTIONS
PROTEZIONE IP 65 / IP 65 PROTECTION
~ 30
~ 50
27
Pressacavo PG09
Cable clamp PG09
Cupola alloggia LED bicolore
Bi-coloured led
Connettore trasparente con Led bicolore rosso/verde
Transparent connector with red/green bi-coloured led
Tipo
Type CLB
36
Ø22.5
51
Pressacavo
Cable clamp
Vite di regolazione
Adjusting screw
Connettore Din 40050
Din 40050 Connector
Connettore M12
M12 Connector
T
C
NO NC
3
2 1
13
26.8
44.5
42.75
22
www.elettrotec.com Ed. 1/2016
Pagina 2 di 2
Sheet 2 of 2
Elettrotec si riserva la facoltà di apportare modifi che tecniche ai prodotti o di cessarne la produzione senza obbligo di
preavviso. Il contatto del pressostato può danneggiarsi quando sottoposto a forti urti o ad alte vibrazioni. È responsabilità
dell’utilizzatore verifi care l’idoneità dei nostri prodotti per ogni particolare applicazione (ad esempio, la verifi ca della
compatibilità dei materiali) e l’uso può essere appropriato solo se dimostrato in test sul campo. Le informazioni tecniche
in questo catalogo si basano su prove effettuate durante lo sviluppo del prodotto e in base ai valori empiricamente
raccolti. Essi non possono essere applicabili in tutti i casi.
Elettrotec reserves the right to technical data of change to the products or halt production without prior notice. The pressure
switch contacts can be damaged when subject to strong shocks or high vibration. It is the responsibility of the user
to test the suitability of our products for the particular application, for example, the verifi cation of material compatibility.
The use may only be appropriate if proven in fi eld tests. The technical information in this catalogue are based on tests
made during product development and based on empirically gathered values. They may not be applicable in all cases.
Membrana / Diaphragm
vedi tabella membrana / guarnizione
see diaphragm / gasket table
RANGE
2 - 5 -10 - 25 - 80
150 - 300
150 - 300
PMC/PPC/PPCF PRESSOSTATI REGOLABILI CON CONTATTI IN SCAMBIO
Adjustable pressure switches with SPDT contacts
SPIEGAZIONE DELLE SIGLE DI ORDINAZIONE / ORDERING INFORMATION
PMC... Pressostato con contatti in scambio
PPC... Pressostato con contatti in scambio
PPCF... Pressostato con contatti in scambio
Membrana disponibile/ - NBR (standard) -5°C...+90°C
Guarnizione NT HNBR -25°C...+140°C
V FKM -5°C...+90°C
S Silicone -30°C...+120°C
Opzioni G Contatti dorati per bassa corrente
T... Taratura in salita al valore richiesto
T...D Taratura in discesa al valore richiesto
- Corpo standard
I Corpo in AISI 303
10A Microinterruttore da 10 A
L24 Con lampada 24 V
L110 Con lampada 110 V
L220 Con lampada 220 V
SG Sgrassati per ossigeno
IN CONFORMITÀ ALLE NORME 2004/108 CE RELAZIONE EMC N° 147E/96.
PMC... Pressure switch with SPDT contacts
PPC... Pressure switch with SPDT contacts
PPCF... Pressure switch with SPDT contacts
Available diaphragm/ - NBR (standard) -5°C to +90°C
Gasket NT HNBR -25°C to +140°C
V FKM -5°C to +90°C
S Silicon -30°C +120°C
Options G Gold-plated contacts for low current
T... Set-point adjustment rising at the required value
T...D Set-point adjustment falling at the required value
- Standard body
I S.S. 303 body
10A Microswitch for 10A
L24 Connector with LED 24 V
L110 Connector with LED 110 V
L220 Connector with LED 220 V
SG Degreased for applications with oxygen
IN COMPLIANCE WITH 2004/108 CE RULES EMC N° 147E/96 REPORT.
SIGLA DI ORDINAZIONE / HOW TO ORDER
PMC... 150 I V T50D
Tipo / Model
PMC/PPC/PPCF
Opzioni / Options
G - SG - T... - T...D
Corpo / Body
(-) - I
CARATTERISTICHE GENERALI / GENERAL SPECIFICATIONS
TIPO
MODEL
CAMPO DI LAVORO
PRESSIONI RELATIVE
ADJUSTMENT
RELATIVE PRESSURE
RANGE
bar
DIMENSIONI
DIMENSIONS
mm
TOLLERANZA
D’INTERVENTO
25°C
TOLERANCE AT
25°C
bar
MAX. PRESSIONE
STATICA
SUPPORTABILE
MAX. STATIC
PRESSURE
bar
ESECUZIONE
EXECUTION
A B C D
PMC 2 0,15 - 2
44 10 G 1/8
BSPT 75
± 0,15 30
NBR
Membrana
Diaphragm
PMC 5 0,2 - 5 ± 0,2 60
PMC10 0,5 - 10 ± 0,3 100
PMC25 10 - 25 ± 0,5 100
PMC80 25 - 80 ± 1,0 150
PPC150 30-150
46 12 G 1/4
BSPT 78 ± 7,0 600
Pistone in acciaio
PPC300 150-300 Steel piston
PPCF150 30-150
72 12 G 1/4
BSPT 92 ± 7,0 600
Pistone in acciaio
PPCF300 150-300 Steel piston